Ampere Computing Logo
Contact Sales
Ampere Computing Logo
Hero Image

Efficiency Footnotes

 

Footnotes:

Data for the Composite Web Service study in the Efficiency campaign is based on single node performance comparisons measured and published by Ampere Computing. Performance data and the test configurations used to gather the data for each application is published on our web site. In particular, the following table shows the composition of a modeled web service based on best available data to determine scale-out behavior through projections and calculations at both Rack and Data center level. The primary applications used in this analysis are:


  1. Rack Level evaluation is based on the total performance required to scale out to 1 Rack of power budget for the Ampere® Altra® Max processors under the weighted load of the stated application composition above. Rack is based on a standard 42U rack with a total power budget of ~14kW including ~10% overhead buffer for networking, mgmt and PDU. Per server power is measured socket level power during fully loaded operation for each architecture, combined with an equivalent system level overhead for motherboard, peripheral and memory power draws. All socket power figures were measured by Ampere during live stress testing and the relative power efficiency ratings can be found at the links provided in the table above.

  2. Data Center level analysis is calculated from the rack level analysis and scaled linearly to fit a medium sized data center specification based approximately on publicly available data for the Bluffdale NSA facility in Bluffdale, UT.(1) The data center modeled is 100k ft2, where 65% of the space is reserved for the server room built on an 8 tile pitch. The total power capacity is roughly 66MW based on a PUE assumption of 1.2. More information on data center rack pitch densities can be found through a variety of publicly available analysis(2) Power savings data was calculated using an average cost of power at $0.11/kW Hour(4) and the difference between the best scaled power(Ampere) against the worst power consumption (Intel).

  3. Carbon equivalencies were calculated using the EPA equivalency calculator.(3)


(1) https://www.npr.org/sections/alltechconsidered/2013/09/23/225381596/booting-up-new-nsa-data-farm-takes-root-in-utah

(2) https://www.racksolutions.com/news/blog/how-many-servers-does-a-data-center-have/

(3) https://www.epa.gov/energy/greenhouse-gases-equivalencies-calculator-calculations-and-references

(4) https://www.eia.gov/electricity/state/


Web TierApplicationComposition WeightComparative Performance Info Reference
Front EndNGINX40%For Altra Max M128-26
Caching TierMemcached10%For Altra Max M128-26
Key Value StoreRedis30%For Altra Max M128-30
Back EndMYSQL20%For Altra Max M128-30

Disclaimer:

All data and information contained in or disclosed by this document are for informational purposes only and are subject to change. Your results may differ. This document is not to be used, copied, or reproduced in its entirety, or presented to others without the express written permission of Ampere®.

This document may contain technical inaccuracies, omissions and typographical errors, and Ampere Computing LLC, and its affiliates (“Ampere”), is under no obligation to update or otherwise correct this information. Ampere makes no representations or warranties of any kind, including express or implied guarantees of noninfringement, merchantability or fitness for a particular purpose, regarding the information contained in this document and assumes no liability of any kind. Ampere® is not responsible for any errors or omissions in this information or for the results obtained from the use of this information. All information in this presentation is provided “as is”, with no guarantee of completeness, accuracy, or timeliness.

This document is not an offer or a binding commitment by Ampere®. Use of the products and services contemplated herein requires the subsequent negotiation and execution of a definitive agreement or is subject to Ampere’s Terms and Conditions for the Sale of Goods.

The technical data contained herein may be subject to U.S. and international export, re-export, or transfer laws, including “deemed export” laws. Use of these materials contrary to U.S. and international law is strictly prohibited.

© 2023 Ampere® Computing LLC. All rights reserved. Ampere®, Ampere® Computing, Altra® and the Ampere® logo are all trademarks of Ampere® Computing LLC or its affiliates. Other product names used in this publication are for identification purposes only and may be trademarks of their respective companies.

Created At : May 30th 2023, 6:25:09 pm
Last Updated At : May 30th 2023, 6:25:11 pm
Ampere Logo

Ampere Computing

4655 Great America Parkway

Suite 601 Santa Clara, CA 95054

image
image
 |  |  |  |  |  | 
© 2022 Ampere Computing LLC. All rights reserved. Ampere, Altra and the A and Ampere logos are registered trademarks or trademarks of Ampere Computing.
This site is running on Ampere Altra Processors.